Continuous Emission Monitoring System
Continuous Emission Monitoring System is applied to monitor emission of chimney in industrial pollution sources. The measuring components include SO2, NOx, O2, dust, humidity, temperature, pressure, flow velocity,etc.Stack emissions testing have obtained CCAEP certification from China Environmental Protection Ministry and a number of technical patents, which is high stable performance.
Applications of system
1.Chimney
2.After the precipitator
3. Channel of chimney entrance
System features
1. Display the real-time monitoring data, transfer data to the client computer and environmental protection department platform simultaneously. Data can be reported, stored, queried, exported, and printed.
2. Adopt high temperature resistant sampling probe and efficient sample gas processing system, low component loss rate.
3. Gas analyzer adopts UV DOAS principle, with fast response speed, strong anti-interference ability, and high measurement accuracy.
4. Industrial stack monitoring has rich interfaces and strong expandability.
5. On-site installation and technical training from technicians. The overall modular design facilitates maintenance. The technical team can provide remote technical support and on-site guidance.
Stack gas monitoring Spec.
Product |
CEMS Continuous emission monitoring system |
Model |
DY-FG200 |
Measuring components |
SO2,NOx,O2,dust,etc temperature,pressure,flow velocity |
Measuring range unit |
Unit:ppm,mg/m3 |
Measuring range |
SO2,NOx:0~50~100~200~500mg/m3,0~500~1000~2500ppm, O2:0~25%. Temp.:0~500℃,humidity:0~40%,pressure:-2.5KPa~+2.5KPa, Flow:0~40m/s. Range can be customized |
Measuring principle |
SO2,NOx:UV DOAS. Dust:laser backscattering ,O2: electrochemistry |
Temperature: thermal resistance Pressure: metal diaphragm Velocity: pitot tube differential pressure Humidity: resistance capacity | |
Sampling method |
extraction |
Response time |
≤200S |
Linearity error |
± 2% F.S. |
Zero drift |
± 2% F.S./24h |
Span drift |
± 2% F.S./24h |
Analog output |
4~20mA DC |
Digital output |
RS232/RS485 |
Power supply |
AC220V+10%,50Hz |
Atmospheric pressure |
80KPa-106KPa |
Purge gas |
Instrument-grade compressed air |
Environment humidity |
≤90%RH |
Ambient temperature |
-20℃~+50℃ |
Installation |
Ground-mounted |
Size |
600mm*800mm*2200mm |
Explosion-proof |
optional |